Solar Gard® – produktegenskaper
Testresultatens värden som är beräknade efter installation på insida av 3 mm klarglas har uppmätts, beräknats och rapporterats i enlighet med kraven från ASTM, ASHRAE och AIMCAL. Resultaten kan variera något mellan olika branschstandarder.
|
Film Type
|
Solar Energy
|
Visible Light
|
|
Thermal Energy
|
UV Light Blocked
T%
|
Total Solar Energy Rejected
|
|
T%
|
A%
|
R%
|
T%
|
Ext.
R% |
Int.
R% |
E
|
Wtr
U-Val |
SC
|
SHGC
|
|
Clear Glass
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1/8" (3mm) Clear glass (No Film)
|
83
|
9
|
8
|
90
|
9
|
9
|
,84
|
1,04
|
,98
|
,85
|
27
|
15
|
|
Aluminum
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Silver 50
|
39
|
38
|
23
|
53
|
23
|
22
|
,77
|
1,00
|
,58
|
,50
|
>99
|
50
|
|
Silver 35
|
25
|
38
|
37
|
34
|
38
|
36
|
,73
|
,98
|
,42
|
,36
|
>99
|
64
|
|
Silver 20
|
12
|
35
|
53
|
16
|
58
|
58
|
,70
|
,97
|
,25
|
,21
|
>99
|
79
|
|
Grey/Silver 15
|
9
|
62
|
29
|
8
|
11
|
49
|
,72
|
,98
|
,31
|
,26
|
>99
|
74
|
|
Bronze/Silver 15
|
7
|
57
|
36
|
8
|
19
|
59
|
,71
|
,97
|
,27
|
,23
|
>99
|
77
|
|
Grey/Silver/Grey 10
|
11
|
64
|
25
|
6
|
10
|
10
|
,79
|
1,01
|
,35
|
,30
|
>99
|
70
|
|
Bronze/Silver/Bronze 10
|
12
|
62
|
26
|
8
|
13
|
14
|
,70
|
,97
|
,34
|
,29
|
>99
|
71
|
|
Quantum
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Quantum/Silver/Quantum 20
|
18
|
75
|
7
|
21
|
8
|
6
|
,85
|
1,04
|
,48
|
,41
|
>99
|
59
|
|
Quantum/Silver/Quantum 10
|
7
|
70
|
23
|
9
|
24
|
22
|
,85
|
1,04
|
,33
|
,28
|
>99
|
72
|
|
Sentinel
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Sentinel 4 Mil Clear OSW
|
78
|
14
|
8
|
89
|
10
|
10
|
,90
|
1,04
|
,95
|
,82
|
>99
|
18
|
|
Sentinel Stainless Steel 45 OSW
|
43
|
43
|
14
|
46
|
15
|
12
|
,88
|
1,04
|
,65
|
,56
|
>99
|
44
|
|
Sentinel Stainless Steel 40 OSW
|
37
|
46
|
17
|
39
|
18
|
16
|
,87
|
1,04
|
,58
|
,50
|
>99
|
50
|
|
Sentinel Stainless Steel 25 OSW
|
23
|
50
|
27
|
24
|
28
|
26
|
,86
|
1,04
|
,43
|
,37
|
>99
|
63
|
|
Sentinel Stainless Steel 15 OSW
|
13
|
49
|
38
|
13
|
40
|
36
|
,83
|
1,04
|
,32
|
,27
|
>99
|
73
|
|
Sentinel Solar Bronze 40 OSW
|
26
|
24
|
50
|
40
|
26
|
23
|
,74
|
1,04
|
,38
|
,33
|
>99
|
67
|
|
Sentinel Solar Bronze 30 OSW
|
18
|
25
|
57
|
30
|
32
|
29
|
,74
|
1,04
|
,29
|
,25
|
>99
|
75
|
|
Sentinel Solar Bronze 20 OSW
|
10
|
25
|
65
|
19
|
40
|
38
|
,73
|
1,04
|
,21
|
,18
|
>99
|
82
|
|
Sentinel Silver 35 OSW
|
25
|
29
|
46
|
34
|
41
|
37
|
,78
|
1,04
|
,39
|
,33
|
>99
|
67
|
|
Sentinel Silver 20 OSW
|
11
|
25
|
64
|
16
|
61
|
58
|
,76
|
1,04
|
,22
|
,18
|
>99
|
82
|
|
Solar Bronze
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Solar Bronze 50
|
29
|
34
|
37
|
45
|
23
|
21
|
,69
|
,96
|
,45
|
,38
|
>99
|
62
|
|
Solar Bronze 35
|
21
|
35
|
44
|
35
|
29
|
27
|
,68
|
,95
|
,35
|
,30
|
>99
|
70
|
|
Solar Bronze 20
|
12
|
38
|
50
|
22
|
37
|
36
|
,66
|
,94
|
,26
|
,22
|
>99
|
78
|
|
Stainless Steel
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Stainless Steel 10
|
9
|
55
|
37
|
9
|
43
|
42
|
,79
|
1,01
|
,29
|
,26
|
>99
|
75
|
|
Stainless Steel 50
|
44
|
44
|
12
|
48
|
13
|
11
|
,89
|
1,07
|
,67
|
,57
|
>99
|
43
|
|
Stainless Steel 35
|
39
|
48
|
13
|
42
|
15
|
12
|
,88
|
1,06
|
,62
|
,53
|
>99
|
47
|
|
Stainless Steel 30
|
31
|
52
|
17
|
34
|
20
|
17
|
,86
|
1,05
|
,54
|
,47
|
>99
|
53
|
|
Stainless Steel 20
|
22
|
55
|
23
|
24
|
28
|
25
|
,84
|
1,04
|
,44
|
,38
|
>99
|
62
|
|
Summer/Winter Low-E
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Silver AG 50 Low E
|
35
|
35
|
30
|
51
|
24
|
27
|
,37
|
,78
|
,50
|
,43
|
>99
|
57
|
|
Silver AG 25 Low E
|
14
|
42
|
44
|
22
|
41
|
48
|
,33
|
,75
|
,27
|
,23
|
>99
|
77
|
|
TrueVue
|
|
|
|
|
|
|
|
|
|
|
|
|
|
TrueVue 40
|
38
|
40
|
22
|
39
|
14
|
10
|
,75
|
,99
|
,57
|
,49
|
>99
|
51
|
|
TrueVue 30
|
27
|
41
|
32
|
31
|
22
|
13
|
,75
|
,99
|
,45
|
,39
|
>99
|
61
|
|
TrueVue 15
|
9
|
40
|
51
|
12
|
45
|
23
|
,75
|
,99
|
,24
|
,20
|
>99
|
80
|
|
TrueVue 5
|
6
|
43
|
51
|
5
|
45
|
8
|
,75
|
,99
|
,21
|
,18
|
>99
|
82
|
Noteringar om testresultaten
1. Testresultatens värden är beräknade efter installation på insida av 4 mm klart enkelglas och 4 mm/12 mm luft/4 mm klart 2-glasfönster.
2. Saint-Gobain Solar Gard LLC är aktiv medlem i AIMCAL (the Association of Industrial Metallizers, Coaters and Laminators), IWFA og EWFA.Testresultatens värden har beräknats enligt CEN-metoden med hjälp av programmet LBNL Window 5.2. Resultaten som endast är uppskattade värden, kan variera något mellan olika branschstandarder.
3. Samtliga resultat har uppmätts efter specifika testprocedurer och standarder. De värden som angivits ovan bör inte användas som godkännande, rekommendation eller certifiering av produkter eller material som testats. Dessa data tillhandahålls enbart för information och vägledning och skall inte betraktas som direkta eller indirekta produktgarantier och bör heller inte brukas för speciella ändamål i försäljningssyfte. Solar Gards garantier skall granskas noggrant innan eventuellt köp av någon av Solar Gards produkter. Testresultat från olika undersökningar bör endast användas separat, aldrig i förhållande till andra data då de kanske inte alltid överensstämmer. Dessa bör alltså tolkas med viss försiktighet. Solar Gard ansvarar inte för variationer i kvalitet, sammansättning, utseende, funktionalitet eller liknande egenskaper som orsakats under omständigheter som Solar Gard inte har kontroll över.
4. Testresultaten för solfaktor sommartid och bländningsreduktion är beräknade genom att jämföra glas med fönsterfilm mot glas utan skyddsfilm.